| Id | 10 | |
| Recipe name | TRF-230-50-12K-F | |
| Part number | PN-009 | |
| Serial number | SN-0009 | |
| Description | 12 kW classe F 230V/50Hz | |
| Mass — m | 44 | kg |
| Created at | 2026-05-22 09:27:46 |
| Voltage primary — U₁N | 230 | V |
| Frequency | 50 | Hz |
| Power 50% rated — S₅₀ | 12000 | VA |
| Power 50% setpoint | 11400 | VA |
| Section winding primary | 16 | mm² |
| Temperature primary rise — θ₂ − θa | 72.8 | °C |
| Ambient temperature — θa | 23 | °C |
| TC0 | 91.3 | °C |
| TC1 | 88.6 | °C |
| Resistance 1 — R₁ | 1.24 | Ω |
| Resistance 2 — R₂ | 0.09 | Ω |
| Tau primary — τ | 3500 | s |
| Duty factor PTTM | 0.5 | |
| Delta pressure — Δp | 0.35 | bar |
| Flow rate — Q | 25 | l/min |
| Current primary — I₁ | 15.3 | A |
| Current secondary — I₂ | 92.7 | A |
| Voltage primary short circuit — U₁cc | 11.2 | V |
| Current primary short circuit | 15.3 | A |
| Power primary short circuit | 171.4 | W |
| Voltage secondary short circuit | 3.1 | V |
| Current secondary short circuit | 92.7 | A |